Governed by: Ministry of Industry and Information Technology of the People's Republic of China
Sponsored by: Northwestern Polytechnical University  Chinese Society Aeronautics and Astronautics
Address: Aviation Building,Youyi Campus, Northwestern Polytechnical University
Study on Cooling Performance of Ribbed Flame Tube Walls in Micro Combustor
CSTR:
Author:
Affiliation:

Civil Aviation University of China,College of Aeronautical Engineering

Clc Number:

V21 TK48

Fund Project:

Basic Research Project of Central Universities of Civil Aviation University of China (3122022046), National Natural Science Foundation of China (Surface Project, Key project, Major project)

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Micro-combustor features small size and compact layout, leading to poor heat dissipation. Applying ribbed cooling design to micro-turbojet engine combustion chambers significantly improves heat dissipation performance. A simplified model of the flame tube was established, with ribs added at different positions on flame tube walls. Three groups of ribs were arranged at varying positions to analyze the effects on airflow within combustor across an inlet velocity range of 10 m/s to 100 m/s, as well as the impact of different rib configurations on heat dissipation. Results show that adding ribs compresses airflow channels, causing acceleration in upstream sections. As airflow passes over ribs, compression effect diminishes, leading to reduced velocity. At the same inlet velocity, temperature variation in the third flame tube is greater, as ribs are closer to inlet and less affected by internal environment, providing better cooling. When ribs are positioned farther from airflow inlet, rear wall influence leads to more turbulent airflow and less stable heat dissipation. At lower airflow velocities, between 10 m/s and 60 m/s, rib cooling effect becomes more pronounced, but at higher velocities (60 m/s to 100 m/s), increased flow rate weakens cooling. These findings hold theoretical significance and practical value for ribbed heat dissipation structure design in micro-combustors.

    Reference
    Related
    Cited by
Get Citation

FU Yu, YAN Xu, YU Jnnli, LIN Han, ZUO Hongfu. Study on Cooling Performance of Ribbed Flame Tube Walls in Micro Combustor[J]. Advances in Aeronautical Science and Engineering,2026,17(5):121-128

Copy
Related Videos

Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:December 05,2024
  • Revised:March 06,2025
  • Adopted:March 13,2025
  • Online: September 30,2025
  • Published:
Article QR Code