Governed by: Ministry of Industry and Information Technology of the People's Republic of China
Sponsored by: Northwestern Polytechnical University  Chinese Society Aeronautics and Astronautics
Address: Aviation Building,Youyi Campus, Northwestern Polytechnical University
Data Fusion-Based Method for Reconstruction of Aerodynamic Thermal Sparse Wind Tunnel Test Data
CSTR:
Author:
Affiliation:

School of Aeronautics, Northwestern Polytechnical University

Clc Number:

V211.22

Fund Project:

D5203231102

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Data-driven modeling methods have become one of the main techniques for predicting aerodynamic thermal behavior in hypersonic applications. However, due to the limitations of wind tunnel experimental conditions, the spatial distribution of aerodynamic thermal wind tunnel experiment data is often sparse, and the sample size is relatively small. This poses challenges in constructing high-performance data-driven aerodynamic thermal prediction models. To address these issues, this paper proposes a reconstruction method for sparse aerodynamic thermal wind tunnel experiment data, integrating a multi-fidelity data fusion modeling approach. First, low-fidelity simulation data for aerodynamic thermal calculations are introduced based on the sparse aerodynamic thermal wind tunnel experiment data to construct a training set for the deep neural network (DNN). Then, a weighted loss function for the DNN is designed. The weighted loss function consists of two components: the loss from the wind tunnel experimental data and the loss from the low-fidelity simulation data. Finally, the DNN is trained to obtain the reconstruction results of the sparse aerodynamic thermal wind tunnel experiment data. Aerodynamic thermal reconstruction is conducted using aerodynamic thermal sparse wind tunnel experiment data from hypersonic wind tunnels for different geometries, including double-ellipsoid, blunt-cone, bicone, and 25°/55° bicone. The results indicate that not only is the normalized root mean square error of the aerodynamic thermal reconstruction results within 9% of the wind tunnel experimental data, but the volume of the reconstructed aerodynamic thermal data is also comparable to that of the low-fidelity numerical simulation results, allowing for a detailed visualization of the aerodynamic thermal distribution in cloud plot form.

    Reference
    Related
    Cited by
Get Citation

Wang Ze, Li Yang, Cheng Siye, Liao Menghao, Song Shufang. Data Fusion-Based Method for Reconstruction of Aerodynamic Thermal Sparse Wind Tunnel Test Data[J]. Advances in Aeronautical Science and Engineering,2026,17(5):24-36

Copy
Related Videos

Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:December 13,2024
  • Revised:March 11,2025
  • Adopted:March 14,2025
  • Online: October 13,2025
  • Published:
Article QR Code