Abstract:To address the difficulty of online monitoring caused by the diverse types and wide size distribution of contaminants in fuel system anti-contamination tests, this study proposes an online measurement method for contaminant mass concentration in fuel based on spectral extinction. The method establishes a theoretical relationship between the measured spectral extinction value ln(I?/I) and particle mass concentration using the Lambert–Beer law, followed by experimental calibration to obtain a linear model between spectral intensity and mass concentration. The calibration was then validated, and the proposed method was further applied to industrial field tests, where its performance was compared with that of the membrane gravimetric method. The results show that the relative measurement error of the spectral extinction method does not exceed ±5% during calibration, and its relative error remains within 10% in industrial field applications. The proposed method enables accurate online measurement of contaminant mass concentration in fuel and provides an effective technical approach for fuel contamination evaluate.